ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm
THEORY OF OPERATION
VACUUM AIR FROM INTERMEDIATE SPACE
1.0.6 Open valve Item No. 5 (Figure 2).
1.0.7 To remove air, attach the vacuum pump with a
hose connection Item No. 6 to the valve Item
No. 5 (Figure 5). The intermediate space is
evacuated to 3 psig for normal operating
conditions.
The instructions below are for Neptune’s optional Double
Diaphragm Kit which is available for the Neptune Series
500, 500-A, and 560 “dia-Pumps”.
Use of a double diaphragm allows diaphragm to be
monitored and provides an early warning upon failure of
either diaphragm allowing repairs to be made before
process fluid mix with the pump hydraulic fluid.
Neptune’s double diaphragm is a kit which may be
retrofitted to any pump currently in service or may be
installed on a new pump at the factory.
Figure 1 illustrates a Double Diaphragm Assembly. An
intermediate plate is located between the oil and liquid
heads with one diaphragm on each side of the
intermediate plate. The Intermediate Plate is connected
to a rupture alarm or pressure switch via a capillary
system. The area between the diaphragms is
evacuated. Rupture in either diaphragm produces an
increase in volume and, therefore, a pressure increase,
which can be sensed by a pressure switch for alarm
purposes.
DISASSEMBLY OF INTERMEDIATE PLATE
1.0.0 Shut pump off and disconnect suction and dis-
charge piping. Remove drain plug and drain
hydraulic fluid from the gearbox.
1.0.1 Remove 8 Screws and remove the liquid head
assembly. Some hydraulic oil and process fluid
will spill out when the head is removed.
1.0.2 The intermediate plate, which is between the
pump heads can be removed easily.
1.0.3 Remove the rupture alarm (pressure switch) and
clean the capillary system.
1.0.4 Replace one or both diaphragms if needed.
1.0.5 To reassemble reverse above procedure. Be
certain that parts align properly.
DOUBLE DIAPHRAGM OPTION
560 PUMP
FIGURE 1