Pump-solutions-group Neptune Series 600 dia-PUMP MODELS 610 thru 647 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Pump-solutions-group Neptune Series 600 dia-PUMP MODELS 610 thru 647. Pump Solutions Group Neptune Series 600 dia-PUMP MODELS 610 thru 647 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
for
NEPTUNE
SERIES 600 “dia-PUMP”
MODELS 610 thru 647
NEPTUNE
CHEMICAL PUMP CO., INC.
Lansdale, PA. 19446 * Tel.: 215-699-8700 * FAX: 215-699-0370
Vue de la page 0
1 2 3 4 5 6 ... 34 35

Résumé du contenu

Page 1 - MODELS 610 thru 647

forNEPTUNESERIES 600 “dia-PUMP”MODELS 610 thru 647NEPTUNECHEMICAL PUMP CO., INC.Lansdale, PA. 19446 * Tel.: 215-699-8700 * FAX: 215-699-0370

Page 2 - SAFETY INSTRUCTIONS:

4.0.2 To reset the relief valve to a higher pressure (the relief valve setting cannot be reduced because ofdesign considerations), instructions are as

Page 3 - TABLE OF CONTENTS

5.0 INSTALLATION OUTDOORSThe “dia-PUMP” is a totally enclosed pump which can be used outdoors or indoors. When installed outdoors, makesure that the p

Page 4

SECTION IIIPUMP MODELS 610 AND 615NORMAL MAINTENANCE7.0 MAINTENANCEUnder normal conditions, the “dia-PUMP” should not require any significant amount o

Page 5 - RETURN GOODS AUTHORIZATION

SECTION IIIPUMP MODELS 620 AND 625NORMAL MAINTENANCE7.1 MAINTENANCEUnder normal conditions, the “dia-Pump” should not require any significant amount o

Page 6 - PARTS ORDERING INSTRUCTIONS

SECTION IIIPUMP MODELS 635, 637 AND 647NORMAL MAINTENANCETO VIEW FIGURE NUMBERS:For Models 635 & 637 refer to Drawing on page 22.For Model 647 ref

Page 7 - INSTALLATION INSTRUCTIONS

7.3.13 Remove control rod assembly with control rod attached (FIG. #0117 for all pumps; #1406 and #1408 forModels 610 &615, #2306 and #2308 for Mo

Page 8

SECTION IVMOTOR OPERATING CONDITIONS8.0 The normal temperature rise for standard motors is 40° C above ambient temperature and, thus, it might appear

Page 9

SECTION VTROUBLE SHOOTING CHARTSYMPTOM CAUSE REMEDY1. Pump Motor Will Not Operate. A. Blown Fuse. Check for short circuitB. Open thermal overload devi

Page 10

SYMPTOM CAUSE REMEDYI. Low discharge pressure. A minimum discharge pressure of50 psi is required to insure propercapacity control.3. Pump delivers err

Page 11

SECTION VIPARTS LIST FOR PUMP MODELS 610 & 615(REFER TO DRAWING NO. 6100, PAGE 18)FIGNO.DESCRIPTION QTY.PARTNO.FIGNO.DESCRIPTION QTY.PARTNO.0101 G

Page 12

WARNINGLOCKOUTS ARE REQUIRED BEFORESERVICING THIS EQUIPMENT.SAFETY INSTRUCTIONS:Shut off/ Lockout pump Power beforeServicing. Be certain pump isolatio

Page 14

SECTION VIPARTS FOR PUMP MODELS 620 & 625(REFER TO DRAWING NO. 6200, PAGE 20)FIG.NO.DESCRIPTION QTY.PARTNO.FIG.NO.DESCRIPTION QTY.PARTNO.0101 Gear

Page 16

SECTION VIPARTS LIST FOR PUMP MODELS 630, 635 & 637(REFER TO DRAWING NO. 6300, PAGE 22)NOTE: N-3 PUMPS HAVE 316SS PUMP HEAD AND 316SS TRIM.N-4 PUM

Page 18

SECTION VIPARTS LIST FOR PUMP MODEL 647(REFER TO DRAWING NO. 6347, PAGE 24)NOTE: N-3 PUMPS HAVE 316SS PUMP HEAD AND 316SS TRIM.N-4 PUMPS HAVE C-20 PUM

Page 20

APPENDUM600 SERIES PVC PUMPTHEORY OF OPERATIONThe NEPTUNE 600 PVC “dia-Pump” is a double diaphragm pump employing the basic drive unit of the Neptunes

Page 22

FIG. NO. PART NO. DESCRIPTION QUANTITY1410 000378 Teflon Diaphragm 11433 100185 Sealing Plate "O" Ring 21434 100188 Control Rod "O"

Page 23

TABLE OF CONTENTSSECTION PARAGRAPH PAGEI--GENERAL DESCRIPTION1LIMITED WARRANTY2PARTS ORDERING INSTRUCTIONS3II --INSTALLATION INSTRUCTIONS41.0 GENERAL4

Page 24

10.0.3 Recommended Spare Parts for PUMP MODELS 620 AND 625It is recommended that the following parts be kept in stock for a pump:FIG. NO. PART NO/ DES

Page 25 - PARTS LIST FOR PUMP MODEL 647

SECTION VIISPECIAL INSTRUCTIONS FOR SERIES 600 ‘DIA-PUMPS” WITH PNEUMATIC STROKE CONTROLRefer to Drawing No. B-00174311.0 FUNCTION OF THE PNEUMATIC ST

Page 26

11.0 PARTS UNIQUE TO PUMPS SUPPLIED WITH NEPTUNE PNEUMATIC STROKE CONTROL.(Refer to Drawing B-001743).PART NO. DESCRIPTION QUANTITY342 Control Mount 1

Page 30

SECTION IGENERAL DESCRIPTIONThe Neptune series 600 “dia-PUMP” is a reliable metering pump of the high-pressure diaphragm type. Underconstant condition

Page 31

SECTION INEPTUNE CHEMICAL PUMP COMPANYLIMITED WARRANTYAll Neptune Pumps are tested at the factory prior to shipment. Each part used in their construct

Page 32 - PART NO. DESCRIPTION QUANTITY

PARTS ORDERING INSTRUCTIONSThe complete model number and serial number of the pump must be furnished to insure prompt and accurate partsservice. These

Page 33

SECTION IIINSTALLATION INSTRUCTIONS1.0 GENERAL1.0.1 UNPACKING & INSPECTIONWhen unpacking a pump or chemical feed system, be certain that no parts

Page 34

Please note Figure 1, indicating the correct rotation. Operation with the incorrect rotation will damage the pump and motor.1.0.8 Please note, that so

Page 35

3.0 DISCHARGE PIPING3.0.1 It is recommended that the “dia-PUMP” operate against a minimum discharge pressure of 50 psig.3.0.2 All Neptune Series 600 “