Pump-solutions-group Neptune Series 560 dia-PUMP Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Pump-solutions-group Neptune Series 560 dia-PUMP. Pump Solutions Group Neptune Series 560 dia-PUMP User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - INSTRUCTION

ZL105645 OPERATING & INSTRUCTION MANUAL for NEPTUNE SERIES 560 “dia-PUMPS” Tel.: 215-69

Page 2 - SAFETY INSTRUCTIONS:

6 2.0 SUCTION PIPING 2.0.1 The suction piping to the pump must be absolutely air tight. It is suggested that the suction piping be tested with low

Page 3 - WARNING

7 4.0.2 To reset the relief valve to a higher pressure, instructions are as follows: 4.0.21 Connect a test set-up as shown in Figure IV below. 4.

Page 4 - TABLE OF CONTENTS

8 5.0 INSTALLATION OUTDOORS The “dia-pump” is a totally enclosed pump which can be used outdoors or indoors. When installed outdoors, make sure that

Page 5 - INTEGRAL TEFC MOTOR

9 SECTION III NORMAL MAINTENANCE 9.0 MAINTENANCE Under normal conditions, the “dia-Pump”does not require any significant amount of maintenance.

Page 6 - RETURN GOODS AUTHORIZATION

10 11.0.0 PROCEDURE FOR REPLACING CONTROL ROD “O” RING (fig. #2334) AND SEALING PLATE “O” RING (FIG. #516-C on Page#18). 11.0.1 Remove hydraulic fl

Page 7

11 12.3.0 Start-up instructions after replacing diaphragm. 12.3.1 Fill gearbox with oil (leaving 1/4" - 1/2" inches of air space). Using

Page 8 - GENERAL

12 SECTION V TROUBLE SHOOTING CHART Symptom Cause Remedy 1. Pump Motor Will Not Operate. A. Blown Fuse. Check for short circuit or overload. B.

Page 9 - FIGURE 1

13 Symptom Cause Remedy *3. Pump delivers erratically. A. Leaky suction line. Repair or replace piping. B. Worn or dirty valves seats, o

Page 10 - DISCHARGE PIPING

14 * Silicone Sealant may be substituted for Gasket “N” indicates parts per new version Valve stacks of all Series 5

Page 11 - FIGURE IV

15 15.0.1 PARTS LIST FOR SERIES.560 "dia-PUMP" FOR OLD STYLE PVC HEAD Pump Serial Number < or = 147994 FOR NEW STYLE PVC HEAD REFFE

Page 12 - INSTALLATION OUTDOORS

WARNING LOCKOUTS ARE REQUIRED BEFORE SERVICING THIS EQUIPMENT. READ INSTRUCTION SERVICE MANUALS FOR DETAILS.

Page 13

16 15.0.2 RECOMMENDED SPARE PARTS: IMPORTANT: When ordering spare parts, please show MODEL NUMBER AND SERIAL NUMBER of pump for which parts are bein

Page 14

17 15.0.4 PARTS FOR "dia..PUMP" ORDERED WITH OTHER THAN STANDARD INTEGRALLY MOUNTED MOTOR (REFER TO DRAWING #000911 on page#19) The fol

Page 15

18 Drawing 5670SERIES 560 "dia PUMP"SECTION VII DRAWINGS

Page 16 - TROUBLE SHOOTING CHART

19 DRAWING # FALP DRAWING # 000911 NEWOLD

Page 17

20 PVC AND KYNAR HEAD OPTION This sheet describes the parts, which are unique to the 560 pumps with the PVC and Kynar Heads. Item No. Descrip

Page 18

21 APPENDIX ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm THEORY OF OPERATION VACUUM AIR FRO

Page 19 - PARTS ORDERING INSTRUCTIONS

22 APPENDIX ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm 1.0.8 Close valve Item No. 5 1.0

Page 20

MATERIAL SAFETY DATA SHEET Page 1 of 4 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Page 21

2 EP 68 Gear Oil Page 2 of 4 6. ACCIDENTAL RELEASE MEASURES SPILLS OR LEAKS: Contain spills, advise EPA, st

Page 22 - DRAWINGS

3 EP 68 Gear Oil Page 3 of 4 11. TOXICOLOGICAL INFORMATION – cont’d SEVERELY SOLVENT REFINED HEAVY PARAFFIN

Page 23 - DRAWING # 000911

WARNING Please read thoroughly before installation, operation or maintenance of any Neptune pump EQUIPMENT MISUSE HAZARD Equipment misuse can cause

Page 24 - PVC AND KYNAR HEAD OPTION

4 EP 68 Gear Oil Page 4 of 4 15. REGULATORY INFORMATION TSCA: This material complies with the TOXIC SUBS

Page 25 - DOUBLE DIAPHRAGM OPTION

5 MATERIAL SAFETY DATA SHEET Page 1 of 4 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Page 26

6 EP 90 Gear Oil Page 2 of 4 6. ACCIDENTAL RELEASE MEASURES SPILLS OR LEAKS: Contain spills, advise EPA,

Page 27 - IRE FIGHTING MEASURES

7 EP 90 Gear Oil Page 3 of 4 11. TOXICOLOGICAL INFORMATION – cont’d SEVERELY SOLVENT REFINED HEAVY PARAF

Page 28

8 EP 90 Gear Oil Page 4 of 4 15. REGULATORY INFORMATION TSCA: This material complies with the TOXIC SUBST

Page 29 - 13. DISPOSAL INFORMATION

9 MAINTENANCE LOG Spare Parts Kit #____________________________________________________________ NEPTUNE CHEMICAL PUMP CO. Tel.: 215-699-8700

Page 30 - 15. REGULATORY INFORMATION

10 © Copyright 2009 Neptune Chemical Pump Company, Printed in U.S.A

Page 31

TABLE OF CONTENTS SECTION PARAGRAPH PAGE I — General Description 1 — Warranty 2 — Parts Ordering Instructions. 3 II — Ins

Page 32

1 SECTION I GENERAL DESCRIPTION The Neptune Series 560 “dia-PUMP” is a reliable metering pump of the hydraulically actuated diaphragm type. Under con

Page 33

2 LIMITED WARRANTY All Neptune Pumps are tested at the factory prior to shipment. Each part used in their construction has been carefully checked fo

Page 34

3 PARTS ORDERING INSTRUCTIONS The complete model number and serial number of the pump must be furnished to insure prompt and accurate parts service.

Page 35 - MAINTENANCE LOG

4 SECTION II INSTALLATION INSTRUCTIONS 1.0 GENERAL 1.0.1 When unpacking a pump or chemical feed system, be certain that no parts are thrown away.

Page 36

5 1.0.9 (Continued) 1.0.11 Set capacity knob to zero and remove Air Bleed Plug from the top of Oil Chamber, refer to drawings 5